Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 9 de 9
Filter
1.
Korean Journal of Radiology ; : 30-41, 2022.
Article in English | WPRIM | ID: wpr-918241

ABSTRACT

Objective@#Computed tomography enterography (CTE) and magnetic resonance enterography (MRE) are considered substitutes for each other for evaluating Crohn’s disease (CD). However, the adequacy of mixing them for routine periodic follow-up for CD has not been established. This study aimed to compare MRE alone with the mixed use of CTE and MRE for the periodic follow-up of small bowel inflammation in patients with CD. @*Materials and Methods@#We retrospectively compared two non-randomized groups, each comprising 96 patients with CD. One group underwent CTE and MRE (MRE followed by CTE or vice versa) for the follow-up of CD (interval, 13–27 months [median, 22 months]), and the other group underwent MRE alone (interval, 15–26 months [median, 21 months]). However, these two groups were similar in clinical characteristics. Three independent readers from three different institutions determined whether inflammation had decreased, remained unchanged, or increased within the entire small bowel and the terminal ileum based on sequential enterography of the patients after appropriate blinding. We compared the two groups for inter-reader agreement and accuracy (terminal ileum only) using endoscopy as the reference standard for enterographic interpretation. @*Results@#The inter-reader agreement was greater in the MRE alone group for the entire small bowel (intraclass correlation coefficient [ICC]: 0.683 vs. 0.473; p = 0.005) and the terminal ileum (ICC: 0.656 vs. 0.490; p = 0.030). The interpretation accuracy was higher in the MRE alone group without statistical significance (70.9%–74.5% vs. 57.9%–64.9% in individual readers; adjusted odds ratio = 3.21; p = 0.077). @*Conclusion@#The mixed use of CTE and MRE was inferior to MRE alone in terms of inter-reader reliability and could probably be less accurate than MRE alone for routine monitoring of small bowel inflammation in patients with CD. Therefore, the consistent use of MRE is favored for this purpose.

2.
Journal of the Korean Radiological Society ; : 406-416, 2021.
Article in English | WPRIM | ID: wpr-901349

ABSTRACT

Purpose@#To evaluate the association between magnetic resonance imaging (MRI)-based texture parameters and Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation in patients with non-mucinous rectal cancer. @*Materials and Methods@#Seventy-nine patients who had pathologically confirmed rectal nonmucinous adenocarcinoma with or without KRAS-mutation and had undergone rectal MRI were divided into a training (n = 46) and validation dataset (n = 33). A texture analysis was performed on the axial T2-weighted images. The association was statistically analyzed using the Mann-Whitney U test. To extract an optimal cut-off value for the prediction of KRAS mutation, a receiver operating characteristic curve analysis was performed. The cut-off value was verified using the validation dataset. @*Results@#In the training dataset, skewness in the mutant group (n = 22) was significantly higher than in the wild-type group (n = 24) (0.221 ± 0.283; -0.006 ± 0.178, respectively, p = 0.003). The area under the curve of the skewness was 0.757 (95% confidence interval, 0.606 to 0.872) with a maximum accuracy of 71%, a sensitivity of 64%, and a specificity of 78%. None of the other texture parameters were associated with KRAS mutation (p > 0.05). When a cut-off value of 0.078 was applied to the validation dataset, this had an accuracy of 76%, a sensitivity of 86%, and a specificity of 68%. @*Conclusion@#Skewness was associated with KRAS mutation in patients with non-mucinous rectal cancer.

3.
Journal of the Korean Radiological Society ; : 406-416, 2021.
Article in English | WPRIM | ID: wpr-893645

ABSTRACT

Purpose@#To evaluate the association between magnetic resonance imaging (MRI)-based texture parameters and Kirsten rat sarcoma viral oncogene homolog (KRAS) mutation in patients with non-mucinous rectal cancer. @*Materials and Methods@#Seventy-nine patients who had pathologically confirmed rectal nonmucinous adenocarcinoma with or without KRAS-mutation and had undergone rectal MRI were divided into a training (n = 46) and validation dataset (n = 33). A texture analysis was performed on the axial T2-weighted images. The association was statistically analyzed using the Mann-Whitney U test. To extract an optimal cut-off value for the prediction of KRAS mutation, a receiver operating characteristic curve analysis was performed. The cut-off value was verified using the validation dataset. @*Results@#In the training dataset, skewness in the mutant group (n = 22) was significantly higher than in the wild-type group (n = 24) (0.221 ± 0.283; -0.006 ± 0.178, respectively, p = 0.003). The area under the curve of the skewness was 0.757 (95% confidence interval, 0.606 to 0.872) with a maximum accuracy of 71%, a sensitivity of 64%, and a specificity of 78%. None of the other texture parameters were associated with KRAS mutation (p > 0.05). When a cut-off value of 0.078 was applied to the validation dataset, this had an accuracy of 76%, a sensitivity of 86%, and a specificity of 68%. @*Conclusion@#Skewness was associated with KRAS mutation in patients with non-mucinous rectal cancer.

4.
Korean Journal of Radiology ; : 987-997, 2020.
Article | WPRIM | ID: wpr-833527

ABSTRACT

Objective@#Measurement of the liver and spleen volumes has clinical implications. Although computed tomography (CT)volumetry is considered to be the most reliable noninvasive method for liver and spleen volume measurement, it has limitedapplication in clinical practice due to its time-consuming segmentation process. We aimed to develop and validate a deeplearning algorithm (DLA) for fully automated liver and spleen segmentation using portal venous phase CT images in variousliver conditions. @*Materials and Methods@#A DLA for liver and spleen segmentation was trained using a development dataset of portal venousCT images from 813 patients. Performance of the DLA was evaluated in two separate test datasets: dataset-1 which included150 CT examinations in patients with various liver conditions (i.e., healthy liver, fatty liver, chronic liver disease, cirrhosis,and post-hepatectomy) and dataset-2 which included 50 pairs of CT examinations performed at ours and other institutions.The performance of the DLA was evaluated using the dice similarity score (DSS) for segmentation and Bland-Altman 95%limits of agreement (LOA) for measurement of the volumetric indices, which was compared with that of ground truth manualsegmentation. @*Results@#In test dataset-1, the DLA achieved a mean DSS of 0.973 and 0.974 for liver and spleen segmentation, respectively,with no significant difference in DSS across different liver conditions (p = 0.60 and 0.26 for the liver and spleen, respectively).For the measurement of volumetric indices, the Bland-Altman 95% LOA was -0.17 ± 3.07% for liver volume and -0.56 ± 3.78%for spleen volume. In test dataset-2, DLA performance using CT images obtained at outside institutions and our institutionwas comparable for liver (DSS, 0.982 vs. 0.983; p = 0.28) and spleen (DSS, 0.969 vs. 0.968; p = 0.41) segmentation. @*Conclusion@#The DLA enabled highly accurate segmentation and volume measurement of the liver and spleen using portalvenous phase CT images of patients with various liver conditions.

5.
Korean Journal of Radiology ; : 413-421, 2020.
Article in English | WPRIM | ID: wpr-811002

ABSTRACT

OBJECTIVE: A widely applicable, non-invasive screening method for non-alcoholic fatty liver disease (NAFLD) is needed. We aimed to develop and validate an index combining computed tomography (CT) and routine clinical data for screening for NAFLD in a large cohort of adults with pathologically proven NAFLD.MATERIALS AND METHODS: This retrospective study included 2218 living liver donors who had undergone liver biopsy and CT within a span of 3 days. Donors were randomized 2:1 into development and test cohorts. CT(L-S) was measured by subtracting splenic attenuation from hepatic attenuation on non-enhanced CT. Multivariable logistic regression analysis of the development cohort was utilized to develop a clinical-CT index predicting pathologically proven NAFLD. The diagnostic performance was evaluated by analyzing the areas under the receiver operating characteristic curve (AUC). The cutoffs for the clinical-CT index were determined for 90% sensitivity and 90% specificity in the development cohort, and their diagnostic performance was evaluated in the test cohort.RESULTS: The clinical-CT index included CT(L-S), body mass index, and aspartate transaminase and triglyceride concentrations. In the test cohort, the clinical-CT index (AUC, 0.81) outperformed CT(L-S) (0.74; p < 0.001) and clinical indices (0.73–0.75; p < 0.001) in diagnosing NAFLD. A cutoff of ≥ 46 had a sensitivity of 89% and a specificity of 41%, whereas a cutoff of ≥ 56.5 had a sensitivity of 57% and a specificity of 89%.CONCLUSION: The clinical-CT index is more accurate than CT(L-S) and clinical indices alone for the diagnosis of NAFLD and may be clinically useful in screening for NAFLD.

6.
Journal of Korean Neurosurgical Society ; : 240-243, 2010.
Article in English | WPRIM | ID: wpr-214810

ABSTRACT

OBJECTIVE: Radiofrequency (RF) medial branch neurotomy is an effective management of lumbar facet syndrome. However, pain may recur after period of time. When pain recurs, it can be repeated, but the successful outcome and duration of relief from repeated procedures are not clearly known. The objective of this study was to determine the success rate and duration of pain relief from repeated radiofrequency medial branch neurotomy for lumbar facet syndrome. METHODS: A retrospective review of medical records was done on 60 consecutive patients, from March of 2006 to February of 2009, who had an initial successful RF neurotomy but subsequently underwent repeated procedures due to recurrence of pain. All procedures were done in carefully selected patients after at least two responsive medial branch nerve blocks. C-arm fluoroscopic guide, impedance, sensory and motor threshold monitoring tools were used for the precise placement of electrodes. Responses of repeated procedures were compared with initial radiofrequency neurotomy for success rates and duration of pain relief. RESULTS: There were 48 females and 12 males. Mean age was 52.4 years (range, 26-83). RF medial branch neurotomy was done on one side in 38 and both sides in 22 patients, each covering at least three segments. Average visual analog scale at last procedure was 6.8. Twelve patients had previous lumbar operations, including 4 patients with instrumentations. Fifty-five patients had two procedures and five patients had three procedures. Mean duration of successful pain relief (> 50% of previous pain for at least 3 months period) after initial radiofrequency neurotomy was 10.9 months (range, 3-28) in 51 (85%) patients. From repeated procedures, successful pain relief was seen in 50 (91%) patients with average duration of 10.2 months (range, 3-24). Five patients had third procedure, which was successful in 4 (80%) patients with mean duration of 9.8 months (range, 5-16). This was not statistically different from initial results. There were no permanent neurological complications from the procedures. CONCLUSION: Results of this study indicate that the frequency of success and durations of relief from repeated RF medial branch neurotomy for lumbar facet syndrome are similar to initial results that provided relatively prolonged period of pain relief without major side effects. Each procedure seems to provide successful pain relief for about 10 months in more than 85% of carefully selected patients when properly done.


Subject(s)
Female , Humans , Male , Electric Impedance , Electrodes , Medical Records , Nerve Block , Recurrence , Retrospective Studies
7.
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons ; : 259-266, 2005.
Article in Korean | WPRIM | ID: wpr-784623

ABSTRACT

0.05) 2. The mean electric activity of the masticatory muscles was found to have decreased during more clenching than resting, but there was no statistically significant difference because of individual difference of measuring values. (p>0.05) 3. The asymmetry index of masticatory muscles in asymmetric groups was significantly greater during clenching compared with controls. (p<0.05) In conclusion, no right-left difference of muscle activities was found in patients with facial asymmetry before orthognathic surgery and 4weeks afterwards. Not only muscular functioning but also many other factors, such as occlusion, temporomandibular joint disorder and trauma, probably affect facial asymmetry and will be analyzed in future studies. And we will need long term follow-up after orthognathic surgery.


Subject(s)
Humans , Deglutition , Electromyography , Facial Asymmetry , Follow-Up Studies , Individuality , Masticatory Muscles , Orthognathic Surgery , Prognathism , Temporal Muscle , Temporomandibular Joint Disorders
8.
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons ; : 164-170, 2005.
Article in Korean | WPRIM | ID: wpr-784611
9.
Journal of the Korean Association of Maxillofacial Plastic and Reconstructive Surgeons ; : 416-425, 2003.
Article in Korean | WPRIM | ID: wpr-784500

ABSTRACT

0.05). In amount of mandibular set back, we found the condylar hange(T2-T1) which had increased tendency from Group 1 to Group 3 and decreased tendency of MM' from Group 1 to 3. but there was no statistical significance (p>0.05). There was some correlation between condylar change and TMJ dysfuction. It seemed that postoperative condylar change had influenced the postoperative TMJ dysfunction, though was no statistical significance (p>0.05). As we have observed the change of condylar axis in the group that complained of TMJ dysfunction after operation in cases of large amount of mandibular set back, do we consider that the more trying to onserve the condylar position will decrease the occurrence rates of the postoperative condylar displacement, TMJ dysfunction and the relapse.


Subject(s)
Female , Humans , Axis, Cervical Vertebra , Orthognathic Surgery , Prognathism , Recurrence , Temporomandibular Joint
SELECTION OF CITATIONS
SEARCH DETAIL